West Bengal Pollution Control Board

Kankinara Laboratory

Panpore More, Kalyani Expressway, Vill. Panpur, P.O. Narrayanpur, Dist: 24-Parganas (N), Pin 743 126,(033) 2502-1189



Station: Ganga at Palta Shitalatala River Basin: GANGA CPCB Station Code: 10161
Sample Date: 02/12/2020 Sample Time: 09:57  
Human Activities: Bathing & washing Weather: Sunny,Clear Water Body: River Ganga
Frequency Of Monitoring: Monthly Use Based Class: B Approximate Depth(Bottom/Table): 3.00 m 
Color & Intensity: Muddy Odour: Odour free Visible effluent discharge: None


Water Quality
Parameter Test Result Unit
  Total Kjeldahl Nitrogen(TKN)      mg/l
  Ammonia-N   0.38   mg/l
  E-coli   11000   MPN/100ml
  pH   8.09   Unit
  BOD   3.60   mg/l
  Conductivity   373.10   µs/cm
  Dissolved O2(DO)   7.20   mg/l
  Fecal Coliform   33000   MPN/100ml
  Fecal Streptococci   1700   MPN/100ml
  Nitrate-N   0.59   mg/l
  Temperature(Water)   22   ⁰C
  Total Coliform   49000   MPN/100ml
  Boron   BDL   mg/l
  Calcium   41.72   mg/l
  COD   13.00   mg/l
  Fluoride   0.27   mg/l
  Magnesium   17.85   mg/l
  Phenolpthalein Alkanity   Nil   mg/l
  Phosphate-P   0.08   mg/l
  Potassium   3.70   mg/l
  Sodium   14.20   mg/l
  Sulphate   22.19   mg/l
  Total Dissolved Solids(TDS)   290.00   mg/l
  Total Fixed Solids(TFS)   206.00   mg/l
  Total Hardness as CaCo3   177.55   mg/l
  Total Suspended Solids(TSS)   42.00   mg/l
  Turbidity   39.30   NTU
  Chloride   9.00   mg/l
  Nitrite N   0.02   mg/l
  Total Alkalinity   157.93   mg/l