West Bengal Pollution Control Board

Kankinara Laboratory

Panpore More, Kalyani Expressway, Vill. Panpur, P.O. Narrayanpur, Dist: 24-Parganas (N), Pin 743 126,(033) 2502-1189



Station: Ganga at Palta Shitalatala River Basin: GANGA CPCB Station Code: 10161
Sample Date: 25/02/2020 Sample Time: 13:50  
Human Activities: Bathing & washing Weather: Cloudy Water Body: River Ganga
Frequency Of Monitoring: Monthly Use Based Class: B Approximate Depth(Bottom/Table): 3.00 m 
Color & Intensity: Muddy Odour: Odour free Visible effluent discharge: None


Water Quality
Parameter Test Result Unit
  Sulphate   34.51   mg/l
  Total Alkalinity   135.34   mg/l
  COD   13.98   mg/l
  Fluoride   0.26   mg/l
  Magnesium   13.10   mg/l
  Nitrite N   0.03   mg/l
  Phenolpthalein Alkanity   5.64   mg/l
  Phosphate-P   0.069   mg/l
  Total Dissolved Solids(TDS)   192.00   mg/l
  Total Fixed Solids(TFS)   42.00   mg/l
  Total Hardness as CaCo3   132.25   mg/l
  Total Kjeldahl Nitrogen(TKN)      mg/l
  Total Suspended Solids(TSS)   62.00   mg/l
  Turbidity   32.40   NTU
  BOD   3.90   mg/l
  Dissolved O2(DO)   7.90   mg/l
  Conductivity   347.30   µs/cm
  E-coli   4000   MPN/100ml
  Fecal Coliform   8000   MPN/100ml
  Fecal Streptococci   700   MPN/100ml
  Nitrate-N   0.47   mg/l
  pH   8.34   Unit
  Temperature   22   ⁰C
  Calcium   31.37   mg/l
  Chloride   14.46   mg/l
  Total Coliform   13000   MPN/100ml
  Boron   BDL   mg/l
  Potassium   3.60   mg/l
  Sodium   20.60   mg/l
  Ammonia-N   0.34   mg/l