West Bengal Pollution Control Board

Kankinara Laboratory

Panpore More, Kalyani Expressway, Vill. Panpur, P.O. Narrayanpur, Dist: 24-Parganas (N), Pin 743 126,(033) 2502-1189



Station: Ganga at Palta Shitalatala River Basin: GANGA CPCB Station Code: 10161
Sample Date: 20/06/2022 Sample Time: 12:35  
Human Activities: Bathing & washing Weather: Cloudy Water Body: River Ganga
Frequency Of Monitoring: Monthly Use Based Class: B Approximate Depth(Bottom/Table): 3.00 m 
Color & Intensity: Muddy Odour: Odour free Visible effluent discharge: None


Water Quality
Parameter Test Result Unit
  Ammonia-N   0.87   mg/l
  BOD   3.20   mg/l
  Conductivity   300.90   µs/cm
  Dissolved O2(DO)   5.90   mg/l
  E-coli   23000   MPN/100ml
  Fecal Coliform   49000   MPN/100ml
  Fecal Streptococci   2200   MPN/100ml
  Nitrate-N   0.24   mg/l
  pH   7.88   Unit
  Temperature(Water)   30   ⁰C
  Total Coliform   79000   MPN/100ml
  Boron   BDL   mg/l
  Calcium   26.23   mg/l
  Chloride   12.99   mg/l
  COD   13.00   mg/l
  Fluoride   0.17   mg/l
  Magnesium   7.07   mg/l
  Nitrite N   0.03   mg/l
  Phenolpthalein Alkanity   NIL   mg/l
  Phosphate-P   0.14   mg/l
  Potassium   3.70   mg/l
  Sodium   11.70   mg/l
  Sulphate   16.79   mg/l
  Total Alkalinity   101.15   mg/l
  Total Dissolved Solids(TDS)   182.00   mg/l
  Total Fixed Solids(TFS)   136.00   mg/l
  Total Hardness as CaCo3   94.55   mg/l
  Total Kjeldahl Nitrogen(TKN)      mg/l
  Total Suspended Solids(TSS)   46.00   mg/l
  Turbidity   31.58   NTU