West Bengal Pollution Control Board

Kankinara Laboratory

Panpore More, Kalyani Expressway, Vill. Panpur, P.O. Narrayanpur, Dist: 24-Parganas (N), Pin 743 126,(033) 2502-1189



Station: Ganga at Palta Shitalatala River Basin: GANGA CPCB Station Code: 10161
Sample Date: 19/05/2022 Sample Time: 11:15  
Human Activities: Bathing & washing Weather: Cloudy,Humid Water Body: River Ganga
Frequency Of Monitoring: Monthly Use Based Class: B Approximate Depth(Bottom/Table): 3.00 m 
Color & Intensity: Muddy Odour: Odour free Visible effluent discharge: None


Water Quality
Parameter Test Result Unit
  Ammonia-N   0.69   mg/l
  BOD   4.00   mg/l
  Conductivity   396.40   µs/cm
  Dissolved O2(DO)   6.40   mg/l
  E-coli   23000   MPN/100ml
  Fecal Coliform   79000   MPN/100ml
  Fecal Streptococci   2200   MPN/100ml
  Nitrate-N   0.24   mg/l
  pH   7.87   Unit
  Temperature(Water)   31   ⁰C
  Total Coliform   240000   MPN/100ml
  Boron   BDL   mg/l
  Calcium   23.32   mg/l
  Chloride   15.99   mg/l
  COD   19.00   mg/l
  Fluoride   0.17   mg/l
  Magnesium   18.56   mg/l
  Nitrite N   0.04   mg/l
  Phenolpthalein Alkanity   Nil   mg/l
  Phosphate-P   0.09   mg/l
  Potassium   3.50   mg/l
  Sodium   18.10   mg/l
  Sulphate   24.79   mg/l
  Total Alkalinity   137.80   mg/l
  Total Dissolved Solids(TDS)   222.00   mg/l
  Total Fixed Solids(TFS)   210.00   mg/l
  Total Hardness as CaCo3   134.55   mg/l
  Total Kjeldahl Nitrogen(TKN)      mg/l
  Total Suspended Solids(TSS)   96.00   mg/l
  Turbidity   85.95   NTU