West Bengal Pollution Control Board

Kankinara Laboratory

Panpore More, Kalyani Expressway, Vill. Panpur, P.O. Narrayanpur, Dist: 24-Parganas (N), Pin 743 126,(033) 2502-1189



Station: Ganga at Palta Shitalatala River Basin: GANGA CPCB Station Code: 10161
Sample Date: 07/01/2022 Sample Time: 12:25  
Human Activities: Bathing & washing Weather: Sunny,Clear Water Body: River Ganga
Frequency Of Monitoring: Monthly Use Based Class: B Approximate Depth(Bottom/Table): 3.00 m 
Color & Intensity: Muddy Odour: Odour free Visible effluent discharge: None


Water Quality
Parameter Test Result Unit
  Ammonia-N   0.30   mg/l
  BOD   4.65   mg/l
  Conductivity   458.20   µs/cm
  Dissolved O2(DO)   7.50   mg/l
  E-coli   33000   MPN/100ml
  Fecal Streptococci   2200   MPN/100ml
  Nitrate-N   0.68   mg/l
  pH   7.93   Unit
  Temperature(Water)   20   ⁰C
  Boron   BDL   mg/l
  Calcium   50.27   mg/l
  Chloride   13.99   mg/l
  COD   17.00   mg/l
  Fluoride   0.33   mg/l
  Fecal Coliform   130000   MPN/100ml
  Phenolpthalein Alkanity   Nil   mg/l
  Total Kjeldahl Nitrogen(TKN)      mg/l
  Potassium   4.00   mg/l
  Sodium   18.20   mg/l
  Sulphate   19.24   mg/l
  Total Alkalinity   168.48   mg/l
  Total Dissolved Solids(TDS)   254.00   mg/l
  Total Fixed Solids(TFS)   216.00   mg/l
  Total Hardness as CaCo3   176.27   mg/l
  Total Suspended Solids(TSS)   52.00   mg/l
  Turbidity   27.89   NTU
  Total Coliform   240000   MPN/100ml
  Magnesium   12.36   mg/l
  Nitrite N   0.04   mg/l
  Phosphate-P   0.15   mg/l