West Bengal Pollution Control Board

Central Laboratory

Paribesh Bhawan, 10A, Block LA, Sector III, Salt Lake City, Kolkata 700 106. (033) 2335-5953



Station: Adi Ganga at Bansdroni (Low Tide) River Basin: GANGA CPCB Station Code: null
Sample Date: 21/02/2022 Sample Time: 12:50  
Human Activities: None Weather: Sunny Water Body: Ganga
Frequency Of Monitoring: Quarterly Use Based Class: E Approximate Depth(Bottom/Table): 0.50 m 
Color & Intensity: Muddy Odour: Odour free Visible effluent discharge: Moderate,Floating Sludge


Water Quality
Parameter Test Result Unit
  BOD   21.25   mg/l
  Dissolved O2(DO)   NIL   mg/l
  Fecal Coliform   2100000   MPN/100ml
  pH   7.14   Unit
  Temperature(Water)   28.0   ⁰C
  Total Coliform   7000000   MPN/100ml
  COD   120.00   mg/l
  Total Suspended Solids(TSS)   40.00   mg/l