West Bengal Pollution Control Board

Kankinara Laboratory

Panpore More, Kalyani Expressway, Vill. Panpur, P.O. Narrayanpur, Dist: 24-Parganas (N), Pin 743 126,(033) 2502-1189



Station: Ganga at Palta, West Bengal River Basin: GANGA CPCB Station Code: 1054
Sample Date: 17/03/2021 Sample Time: 12:30  
Human Activities: Bathing & washing Weather: Sunny,Clear Water Body: Ganga
Frequency Of Monitoring: Monthly Use Based Class: B Approximate Depth(Bottom/Table): 3.00 m 
Color & Intensity: Muddy Odour: Odour free Visible effluent discharge: None


Water Quality
Parameter Test Result Unit
  Ammonia-N   0.14   mg/l
  BOD   1.90   mg/l
  Conductivity   405.00   µs/cm
  Dissolved O2(DO)   6.50   mg/l
  E-coli   33000   MPN/100ml
  Fecal Coliform   79000   MPN/100ml
  Fecal Streptococci   460   MPN/100ml
  Nitrate-N   0.69   mg/l
  pH   7.94   Unit
  Temperature(Water)   30   ⁰C
  Total Coliform   130000   MPN/100ml
  Boron   BDL   mg/l
  Calcium   61.40   mg/l
  Chloride   13.00   mg/l
  COD   9.00   mg/l
  Fluoride   0.30   mg/l
  Magnesium   4.14   mg/l
  Nitrite N   0.06   mg/l
  Phenolpthalein Alkanity   Nil   mg/l
  Phosphate-P   0.10   mg/l
  Potassium   4.80   mg/l
  Sodium   17.50   mg/l
  Sulphate   15.44   mg/l
  Total Alkalinity   154.47   mg/l
  Total Dissolved Solids(TDS)   216.00   mg/l
  Total Fixed Solids(TFS)   228.00   mg/l
  Total Hardness as CaCo3   170.21   mg/l
  Total Kjeldahl Nitrogen(TKN)      mg/l
  Total Suspended Solids(TSS)   70.00   mg/l
  Turbidity   54.70   NTU