West Bengal Pollution Control Board

Kankinara Laboratory

Panpore More, Kalyani Expressway, Vill. Panpur, P.O. Narrayanpur, Dist: 24-Parganas (N), Pin 743 126,(033) 2502-1189



Station: Ganga at Palta, West Bengal River Basin: GANGA CPCB Station Code: 1054
Sample Date: 16/07/2020 Sample Time: 14:25  
Human Activities: Bathing & Washing Weather: Sunny,Hot,Humid Water Body: Ganga
Frequency Of Monitoring: Monthly Use Based Class: B Approximate Depth(Bottom/Table): 3.00 m 
Color & Intensity: Muddy Odour: Odour free Visible effluent discharge: None


Water Quality
Parameter Test Result Unit
  E-coli   8000   MPN/100ml
  Fecal Coliform   13000   MPN/100ml
  Fecal Streptococci   800   MPN/100ml
  Nitrate-N   0.33   mg/l
  Temperature(Water)   31   ⁰C
  Total Coliform   50000   MPN/100ml
  Calcium   22.63   mg/l
  Chloride   13.0   mg/l
  COD   10.21   mg/l
  Fluoride   0.43   mg/l
  Magnesium   8.25   mg/l
  Phenolpthalein Alkanity   Nil   mg/l
  Phosphate-P   0.07   mg/l
  Potassium   3.9   mg/l
  Sodium   9.0   mg/l
  Sulphate   19.42   mg/l
  Total Dissolved Solids(TDS)   124.00   mg/l
  Total Hardness as CaCo3   90.55   mg/l
  Total Kjeldahl Nitrogen(TKN)      mg/l
  Total Suspended Solids(TSS)   254.00   mg/l
  Turbidity   236.00   NTU
  Ammonia-N   0.12   mg/l
  Dissolved O2(DO)   4.50   mg/l
  pH   8.09   Unit
  Nitrite N   0.02   mg/l
  Total Fixed Solids(TFS)   116.00   mg/l
  BOD   1.85   mg/l
  Conductivity   229.90   µs/cm
  Boron   BDL   mg/l
  Total Alkalinity   103.38   mg/l