West Bengal Pollution Control Board

Kankinara Laboratory

Panpore More, Kalyani Expressway, Vill. Panpur, P.O. Narrayanpur, Dist: 24-Parganas (N), Pin 743 126,(033) 2502-1189



Station: Ganga at Palta, West Bengal River Basin: GANGA CPCB Station Code: 1054
Sample Date: 17/07/2019 Sample Time: 12:15  
Human Activities: Bathing, Washing Weather: Sunny clear Water Body: Ganga
Frequency Of Monitoring: Monthly Use Based Class: B Approximate Depth(Bottom/Table): 2.50 m 
Color & Intensity: Muddy Odour: Odour free Visible effluent discharge: None


Water Quality
Parameter Test Result Unit
  Ammonia-N   0.12   mg/l
  BOD   5.5   mg/l
  Conductivity   236.3   µs/cm
  Dissolved O2(DO)   6.3   mg/l
  Fecal Coliform   130000   MPN/100ml
  Nitrate-N   0.25   mg/l
  pH   8.02   Unit
  Temperature   32   ⁰C
  Total Coliform   240000   MPN/100ml
  Boron   NT   mg/l
  Calcium   23.0   mg/l
  Chloride   7.0   mg/l
  COD   14.4   mg/l
  Fluoride   0.26   mg/l
  Magnesium   8.0   mg/l
  Nitrite N   0.016   mg/l
  Phenolpthalein Alkanity   0.0   mg/l
  Phosphate-P   0.070   mg/l
  Potassium   3.80   mg/l
  Sodium   8.70   mg/l
  Sulphate   18.49   mg/l
  Total Alkalinity   82.66   mg/l
  Total Dissolved Solids(TDS)   200.0   mg/l
  Total Fixed Solids(TFS)   30.0   mg/l
  Total Hardness as CaCo3   91.0   mg/l
  Total Kjeldahl Nitrogen(TKN)      mg/l
  Total Suspended Solids(TSS)   364.0   mg/l
  Turbidity   269.0   NTU