West Bengal Pollution Control Board

Kankinara Laboratory

Panpore More, Kalyani Expressway, Vill. Panpur, P.O. Narrayanpur, Dist: 24-Parganas (N), Pin 743 126,(033) 2502-1189



Station: Ganga at Palta, West Bengal River Basin: GANGA CPCB Station Code: 1054
Sample Date: 22/05/2019 Sample Time: 12:20  
Human Activities: Bathing, Washing Weather: Sunny Water Body: Ganga
Frequency Of Monitoring: Monthly Use Based Class: B Approximate Depth(Bottom/Table): 2.50 m 
Color & Intensity: clear Odour: None Visible effluent discharge: None


Water Quality
Parameter Test Result Unit
  Ammonia-N   0.18   mg/l
  Conductivity   287.00   µs/cm
  Dissolved O2(DO)   6.50   mg/l
  Fecal Coliform   170000   MPN/100ml
  Fluoride   0.25   mg/l
  Total Suspended Solids(TSS)   80.00   mg/l
  Nitrate-N   0.41   mg/l
  pH   7.78   Unit
  Temperature   33.0   ⁰C
  Total Coliform   220000   MPN/100ml
  Boron   NT   mg/l
  BOD   2.10   mg/l
  Calcium   28.00   mg/l
  Chloride   19.07   mg/l
  COD   14.08   mg/l
  Magnesium   11.00   mg/l
  Phenolpthalein Alkanity   NIL   mg/l
  Phosphate-P   0.04   mg/l
  Potassium   6.80   mg/l
  Sodium   20.70   mg/l
  Sulphate   11.02   mg/l
  Total Alkalinity   100.00   mg/l
  Total Dissolved Solids(TDS)   188.00   mg/l
  Total Fixed Solids(TFS)   112.00   mg/l
  Total Hardness as CaCo3   116.00   mg/l
  Total Kjeldahl Nitrogen(TKN)   0.77   mg/l
  Turbidity   131.00   NTU
  Nitrite N   0.09   mg/l