West Bengal Pollution Control Board

Kankinara Laboratory

Panpore More, Kalyani Expressway, Vill. Panpur, P.O. Narrayanpur, Dist: 24-Parganas (N), Pin 743 126,(033) 2502-1189



Station: Ganga at Palta, West Bengal River Basin: GANGA CPCB Station Code: 1054
Sample Date: 04/07/2022 Sample Time: 12:30  
Human Activities: Bathing & washing Weather: Sunny,Clear Water Body: Ganga
Frequency Of Monitoring: Monthly Use Based Class: B Approximate Depth(Bottom/Table): 3.00 m 
Color & Intensity: Muddy Odour: Odour free Visible effluent discharge: Moderate


Water Quality
Parameter Test Result Unit
  Ammonia-N   0.28   mg/l
  BOD   2.10   mg/l
  Conductivity   231.60   µs/cm
  Dissolved O2(DO)   5.80   mg/l
  E-coli   13000   MPN/100ml
  Fecal Coliform   49000   MPN/100ml
  Fecal Streptococci   790   MPN/100ml
  Nitrate-N   0.33   mg/l
  pH   7.90   Unit
  Temperature(Water)   32   ⁰C
  Total Coliform   79000   MPN/100ml
  Boron   BDL   mg/l
  Calcium   28.13   mg/l
  Chloride   12.99   mg/l
  COD   9.00   mg/l
  Fluoride   0.12   mg/l
  Magnesium   6.82   mg/l
  Nitrite N   0.02   mg/l
  Phenolpthalein Alkanity   Nil   mg/l
  Phosphate-P   0.18   mg/l
  Potassium   4.90   mg/l
  Sodium   10.40   mg/l
  Sulphate   18.72   mg/l
  Total Alkalinity   94.00   mg/l
  Total Dissolved Solids(TDS)   134.00   mg/l
  Total Fixed Solids(TFS)   166.00   mg/l
  Total Hardness as CaCo3   98.25   mg/l
  Total Kjeldahl Nitrogen(TKN)      mg/l
  Total Suspended Solids(TSS)   126.00   mg/l
  Turbidity   131.50   NTU