West Bengal Pollution Control Board

Kankinara Laboratory

Panpore More, Kalyani Expressway, Vill. Panpur, P.O. Narrayanpur, Dist: 24-Parganas (N), Pin 743 126,(033) 2502-1189



Station: Ganga at Palta, West Bengal River Basin: GANGA CPCB Station Code: 1054
Sample Date: 19/05/2022 Sample Time: 11:40  
Human Activities: Bathing & washing Weather: Cloudy,Humid Water Body: Ganga
Frequency Of Monitoring: Monthly Use Based Class: B Approximate Depth(Bottom/Table): 3.00 m 
Color & Intensity: Muddy Odour: Odour free Visible effluent discharge: None


Water Quality
Parameter Test Result Unit
  Ammonia-N   0.16   mg/l
  BOD   2.70   mg/l
  Conductivity   368.00   µs/cm
  Dissolved O2(DO)   6.90   mg/l
  E-coli   13000   MPN/100ml
  Fecal Coliform   49000   MPN/100ml
  Fecal Streptococci   790   MPN/100ml
  Nitrate-N   0.43   mg/l
  pH   8.00   Unit
  Temperature(Water)   31   ⁰C
  Total Coliform   79000   MPN/100ml
  Boron   BDL   mg/l
  Calcium   32.06   mg/l
  Chloride   16.99   mg/l
  COD   11.00   mg/l
  Fluoride   0.20   mg/l
  Magnesium   11.49   mg/l
  Nitrite N   0.04   mg/l
  Phenolpthalein Alkanity   Nil   mg/l
  Phosphate-P   0.18   mg/l
  Potassium   3.70   mg/l
  Sodium   17.70   mg/l
  Sulphate   29.89   mg/l
  Total Alkalinity   129.92   mg/l
  Total Dissolved Solids(TDS)   208.00   mg/l
  Total Fixed Solids(TFS)   216.00   mg/l
  Total Hardness as CaCo3   128.00   mg/l
  Total Kjeldahl Nitrogen(TKN)      mg/l
  Total Suspended Solids(TSS)   122.00   mg/l
  Turbidity   108.70   NTU