West Bengal Pollution Control Board

Kankinara Laboratory

Panpore More, Kalyani Expressway, Vill. Panpur, P.O. Narrayanpur, Dist: 24-Parganas (N), Pin 743 126,(033) 2502-1189



Station: Ganga at Palta, West Bengal River Basin: GANGA CPCB Station Code: 1054
Sample Date: 10/09/2021 Sample Time: 13:05  
Human Activities: Bathing & washing Weather: Sunny,Clear,Hot Water Body: Ganga
Frequency Of Monitoring: Monthly Use Based Class: B Approximate Depth(Bottom/Table): 3.00 m 
Color & Intensity: Muddy Odour: Odour free Visible effluent discharge: None


Water Quality
Parameter Test Result Unit
  Ammonia-N   0.14   mg/l
  BOD   3.75   mg/l
  Conductivity   281.90   µs/cm
  Dissolved O2(DO)   4.00   mg/l
  E-coli   17000   MPN/100ml
  Fecal Coliform   110000   MPN/100ml
  Fecal Streptococci   1300   MPN/100ml
  Nitrate-N   0.94   mg/l
  pH   7.86   Unit
  Temperature(Water)   32.5   ⁰C
  Total Coliform   170000   MPN/100ml
  Boron   BDL   mg/l
  Calcium   22.00   mg/l
  Chloride   7.00   mg/l
  COD   13.33   mg/l
  Fluoride   0.51   mg/l
  Magnesium   15.25   mg/l
  Nitrite N   0.03   mg/l
  Phenolpthalein Alkanity   Nil   mg/l
  Phosphate-P   0.25   mg/l
  Potassium   5.10   mg/l
  Sodium   9.70   mg/l
  Sulphate   12.77   mg/l
  Total Alkalinity   103.71   mg/l
  Total Dissolved Solids(TDS)   178.00   mg/l
  Total Fixed Solids(TFS)   348.00   mg/l
  Total Hardness as CaCo3   117.65   mg/l
  Total Kjeldahl Nitrogen(TKN)      mg/l
  Total Suspended Solids(TSS)   386.00   mg/l
  Turbidity   316.00   NTU